MCL Intelligent High Efficiency Denitrification (MIHE-SNCR) Technology Introduction2024-06-13

MCL Intelligent High Efficiency Denitrification (iHe-SNCR) Principle

Based on the SNCR denitrification principle, ammonia or urea solution is used to reduce NOx in the flue gas without a catalyst to achieve the purpose of denitrification. The main reaction chemical equation is as follows:

1.jpg

However, it has been found through multiple project practices that when the temperature is too high or the NH3 is excessive or the O2 content is too high, the following side reactions will occur: 4NH3 + 5O2 → 4NO + 6H2OWhen the content is too low, it is not conducive to the denitration reduction reaction. This is also the reason why the NOx concentration increases instead of decreases during SNCR denitration, even though the injection amount of reducing agent is increased.O2

Last news

Beijing MCL Technology attended the 25th International Cement Technology and Equipment Exhibition The denitrification system technical transformation project successfully met the standards, demonstrating our company's service and technical strength South African customers inspected our company's projects and highly recognized our company's efficient denitrification(MIHE-SNCR) technology MIHE-SNCR Intelligent and efficient denitrification system wins three new orders for cement projects MCL Intelligent High Efficiency Denitrification (MIHE-SNCR) Technology Introduction MCL Intelligent High Efficiency Denitrification (MIHE-SNCR) Technology Introduction MCL Technology (Beijing) Co., Ltd. Brief Introduction of Denitrification Technology Before 2030, the focus will be on implementing the "Ten Actions for Carbon Peaking" Desulfurization equipment in the production process of the chemical industry More